@@ -0,0 +1,310 @@
|
|
|
|
|
+// Conformance of the protocol layer against transcripts recorded from the
|
|
|
|
|
+// original meCoffee V10 firmware image running in simavr.
|
|
|
|
|
+//
|
|
|
|
|
+// Regenerate the fixture with `python3 sim/generate_transcripts.py` in the
|
|
|
|
|
+// meCoffee firmware workspace and copy it to test/fixtures/. Every received
|
|
|
|
|
+// line was produced by the unmodified firmware; the `send` strings are what
|
|
|
|
|
+// this client must emit for the listed settings.
|
|
|
|
|
+import 'dart:convert';
|
|
|
|
|
+import 'dart:io';
|
|
|
|
|
+
|
|
|
|
|
+import 'package:flutter_test/flutter_test.dart';
|
|
|
|
|
+import 'package:mebarista/models/machine_state.dart';
|
|
|
|
|
+import 'package:mebarista/services/me_coffee_protocol.dart';
|
|
|
|
|
+
|
|
|
|
|
+final Map<String, dynamic> fixture =
|
|
|
|
|
+ jsonDecode(
|
|
|
|
|
+ File('test/fixtures/v10_golden_transcripts.json').readAsStringSync(),
|
|
|
|
|
+ )
|
|
|
|
|
+ as Map<String, dynamic>;
|
|
|
|
|
+
|
|
|
|
|
+Object? field(MachineState s, String name) => switch (name) {
|
|
|
|
|
+ 'brewTemperature' => s.brewTemperature,
|
|
|
|
|
+ 'steamTemperature' => s.steamTemperature,
|
|
|
|
|
+ 'pidP' => s.pidP,
|
|
|
|
|
+ 'pidI' => s.pidI,
|
|
|
|
|
+ 'pidD' => s.pidD,
|
|
|
|
|
+ 'pidIWindDownMin' => s.pidIWindDownMin,
|
|
|
|
|
+ 'pidIWindDownMax' => s.pidIWindDownMax,
|
|
|
|
|
+ 'pidPollingInterval' => s.pidPollingInterval,
|
|
|
|
|
+ 'preinfusionEnabled' => s.preinfusionEnabled,
|
|
|
|
|
+ 'preinfusionTime' => s.preinfusionTime,
|
|
|
|
|
+ 'preinfusionPauseTime' => s.preinfusionPauseTime,
|
|
|
|
|
+ 'valveClosedWhilePaused' => s.valveClosedWhilePaused,
|
|
|
|
|
+ 'proActivePercentage' => s.proActivePercentage,
|
|
|
|
|
+ 'autoShutoffMinutes' => s.autoShutoffMinutes,
|
|
|
|
|
+ 'maxShotTime' => s.maxShotTime,
|
|
|
|
|
+ 'continuousMode' => s.continuousMode,
|
|
|
|
|
+ 'installedAsTimer' => s.installedAsTimer,
|
|
|
|
|
+ 'powerButtonFlipsBack' => s.powerButtonFlipsBack,
|
|
|
|
|
+ 'output0' => s.output0,
|
|
|
|
|
+ 'output1' => s.output1,
|
|
|
|
|
+ 'output2' => s.output2,
|
|
|
|
|
+ 'wakeupEnabled' => s.wakeupEnabled,
|
|
|
|
|
+ 'wakeupTime' => s.wakeupTime,
|
|
|
|
|
+ 'shutdownEnabled' => s.shutdownEnabled,
|
|
|
|
|
+ 'shutdownTime' => s.shutdownTime,
|
|
|
|
|
+ 'pressureStart' => s.pressureStart,
|
|
|
|
|
+ 'pressureEnd' => s.pressureEnd,
|
|
|
|
|
+ 'pressurePeriod' => s.pressurePeriod,
|
|
|
|
|
+ _ => throw ArgumentError('unmapped MachineState field $name'),
|
|
|
|
|
+};
|
|
|
|
|
+
|
|
|
|
|
+Object clientValue(Map<String, dynamic> w) => switch (w['kind']) {
|
|
|
|
|
+ 'double' => (w['value'] as num).toDouble(),
|
|
|
|
|
+ 'int' => w['value'] as int,
|
|
|
|
|
+ 'bool' => w['value'] as bool,
|
|
|
|
|
+ 'time' => w['value'] as String,
|
|
|
|
|
+ _ => throw ArgumentError('unknown kind ${w['kind']}'),
|
|
|
|
|
+};
|
|
|
|
|
+
|
|
|
|
|
+Matcher expectation(Object? expected) =>
|
|
|
|
|
+ expected is double ? closeTo(expected, 1e-6) : equals(expected);
|
|
|
|
|
+
|
|
|
|
|
+MachineState parseAll(Iterable<String> lines, [MachineState? start]) =>
|
|
|
|
|
+ lines.fold(
|
|
|
|
|
+ start ?? MachineState(),
|
|
|
|
|
+ (state, line) => MeCoffeeProtocol.parse(line, state),
|
|
|
|
|
+ );
|
|
|
|
|
+
|
|
|
|
|
+List<String> scenarioLines(String name) {
|
|
|
|
|
+ final scenario = (fixture['scenarios'] as List)
|
|
|
|
|
+ .cast<Map<String, dynamic>>()
|
|
|
|
|
+ .firstWhere((s) => s['name'] == name);
|
|
|
|
|
+ return [
|
|
|
|
|
+ for (final e in (scenario['receive'] as List).cast<Map<String, dynamic>>())
|
|
|
|
|
+ e['line'] as String,
|
|
|
|
|
+ ];
|
|
|
|
|
+}
|
|
|
|
|
+
|
|
|
|
|
+void main() {
|
|
|
|
|
+ final writes = (fixture['setting_writes'] as List)
|
|
|
|
|
+ .cast<Map<String, dynamic>>();
|
|
|
|
|
+
|
|
|
|
|
+ test('fixture comes from the bundled V10 image', () {
|
|
|
|
|
+ final hex = File('meBarista_for_Android/assets/meCoffee-V10.hex');
|
|
|
|
|
+ if (!hex.existsSync()) return;
|
|
|
|
|
+ expect(
|
|
|
|
|
+ fixture['firmware_hex_sha256'],
|
|
|
|
|
+ 'ba8a21559881bac6a624b5cccb372fc31cafeee70c76babcb41e57f5e476c4ac',
|
|
|
|
|
+ );
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ group('V10 firmware conformance: settings writes', () {
|
|
|
|
|
+ for (final w in writes) {
|
|
|
|
|
+ final key = w['key'] as String;
|
|
|
|
|
+
|
|
|
|
|
+ test('$key: encoder emits the command the firmware accepted', () {
|
|
|
|
|
+ expect(MeCoffeeProtocol.encodeSet(key, clientValue(w)), w['send']);
|
|
|
|
|
+ final reply = (w['reply'] as List).cast<String>();
|
|
|
|
|
+ expect(reply, hasLength(1));
|
|
|
|
|
+ expect(reply.single, startsWith('cmd set s_$key '));
|
|
|
|
|
+ expect(reply.single, endsWith(' OK'));
|
|
|
|
|
+ expect(reply.single, isNot(contains('NOT OK')));
|
|
|
|
|
+ final stored = reply.single.split(' ')[3];
|
|
|
|
|
+ expect((w['readback'] as List).single, 'cmd get $key $stored OK');
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('$key: firmware echo and readback parse to the intended value', () {
|
|
|
|
|
+ final expected = expectation(w['expect']);
|
|
|
|
|
+ final echoed = parseAll((w['reply'] as List).cast<String>());
|
|
|
|
|
+ expect(field(echoed, w['field'] as String), expected);
|
|
|
|
|
+ final readBack = parseAll((w['readback'] as List).cast<String>());
|
|
|
|
|
+ expect(field(readBack, w['field'] as String), expected);
|
|
|
|
|
+ });
|
|
|
|
|
+ }
|
|
|
|
|
+
|
|
|
|
|
+ test('every written setting survives a controller reboot', () {
|
|
|
|
|
+ final dump = (fixture['dump_after_reboot'] as List).cast<String>();
|
|
|
|
|
+ expect(dump.first, 'cmd dump OK');
|
|
|
|
|
+ expect(dump.last, 'cmd dump 35 OK');
|
|
|
|
|
+ final state = parseAll(dump);
|
|
|
|
|
+ for (final w in writes) {
|
|
|
|
|
+ expect(
|
|
|
|
|
+ field(state, w['field'] as String),
|
|
|
|
|
+ expectation(w['expect']),
|
|
|
|
|
+ reason: w['key'] as String,
|
|
|
|
|
+ );
|
|
|
|
|
+ }
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('a batched settings write is acknowledged command by command', () {
|
|
|
|
|
+ final batch = fixture['batched_write'] as Map<String, dynamic>;
|
|
|
|
|
+ final byKey = {for (final w in writes) w['key'] as String: w};
|
|
|
|
|
+ final payload = ['pinbl', 'pistrt', 'piprd', 'pivlv']
|
|
|
|
|
+ .map((k) => MeCoffeeProtocol.encodeSet(k, clientValue(byKey[k]!)))
|
|
|
|
|
+ .join();
|
|
|
|
|
+ expect(payload, batch['send']);
|
|
|
|
|
+ final replies = (batch['reply'] as List).cast<String>();
|
|
|
|
|
+ expect(replies, hasLength(4));
|
|
|
|
|
+ expect(
|
|
|
|
|
+ replies.every((r) => r.endsWith(' OK') && !r.contains('NOT')),
|
|
|
|
|
+ isTrue,
|
|
|
|
|
+ );
|
|
|
|
|
+ });
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ group('V10 firmware conformance: connection start-up', () {
|
|
|
|
|
+ final init = fixture['init'] as Map<String, dynamic>;
|
|
|
|
|
+ final received = (init['receive'] as List).cast<String>();
|
|
|
|
|
+ final state = parseAll([
|
|
|
|
|
+ ...(init['boot'] as List).cast<String>(),
|
|
|
|
|
+ ...received,
|
|
|
|
|
+ ]);
|
|
|
|
|
+
|
|
|
|
|
+ test('controller identity is recognised as modern (not V4) firmware', () {
|
|
|
|
|
+ expect(received, contains('cmd uname meCoffee pcb V9 30 149 15 OK'));
|
|
|
|
|
+ expect(state.firmwareVersion, contains('pcb V9'));
|
|
|
|
|
+ expect(state.isLegacyV4Firmware, isFalse);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('dump delivers all 35 settings between start and end markers', () {
|
|
|
|
|
+ final gets = received.where((l) => l.startsWith('cmd get '));
|
|
|
|
|
+ expect(gets, hasLength(35));
|
|
|
|
|
+ expect(received, contains('cmd dump OK'));
|
|
|
|
|
+ expect(received, contains('cmd dump 35 OK'));
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('factory defaults decode with the client scaling', () {
|
|
|
|
|
+ expect(state.brewTemperature, 101.0);
|
|
|
|
|
+ expect(state.steamTemperature, 125.0);
|
|
|
|
|
+ expect(state.pidP, 20);
|
|
|
|
|
+ expect(state.pidI, closeTo(0.30, 1e-9));
|
|
|
|
|
+ expect(state.pidD, 128);
|
|
|
|
|
+ expect(state.pidIWindDownMin, closeTo(1000 / 655.36, 1e-9));
|
|
|
|
|
+ expect(state.pidIWindDownMax, closeTo(13107 / 655.36, 1e-9));
|
|
|
|
|
+ expect(state.pidPollingInterval, 1000);
|
|
|
|
|
+ expect(state.preinfusionEnabled, isFalse);
|
|
|
|
|
+ expect(state.preinfusionTime, 3.0);
|
|
|
|
|
+ expect(state.preinfusionPauseTime, 3.0);
|
|
|
|
|
+ expect(state.continuousMode, isTrue);
|
|
|
|
|
+ expect(state.proActivePercentage, 33);
|
|
|
|
|
+ expect(state.autoShutoffMinutes, 60);
|
|
|
|
|
+ expect([state.output0, state.output1, state.output2], [112, 98, 118]);
|
|
|
|
|
+ expect(
|
|
|
|
|
+ [state.pressureStart, state.pressureEnd, state.pressurePeriod],
|
|
|
|
|
+ [100, 100, 25],
|
|
|
|
|
+ );
|
|
|
|
|
+ expect(state.maxShotTime, 0);
|
|
|
|
|
+ expect(state.grinderCounter, 0);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('telemetry decodes the boiler sensor', () {
|
|
|
|
|
+ expect(state.temperature, closeTo(92.83, 1e-9));
|
|
|
|
|
+ expect(state.targetTemperature, 101.0);
|
|
|
|
|
+ });
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ group('V10 firmware conformance: replies the client must ignore', () {
|
|
|
|
|
+ final rejections = (fixture['rejections'] as List)
|
|
|
|
|
+ .cast<Map<String, dynamic>>();
|
|
|
|
|
+
|
|
|
|
|
+ test('unknown keys, CR-terminated lines and diagnostics leave state', () {
|
|
|
|
|
+ final base = parseAll(['cmd get tmpsp 9350 OK']);
|
|
|
|
|
+ for (final r in rejections) {
|
|
|
|
|
+ final send = r['send'] as String;
|
|
|
|
|
+ if (send.startsWith('cmd set tmpsp 9350 OK')) continue;
|
|
|
|
|
+ for (final line in (r['reply'] as List).cast<String>()) {
|
|
|
|
|
+ final next = MeCoffeeProtocol.parse(line, base);
|
|
|
|
|
+ expect(identical(next, base), isTrue, reason: '$send -> "$line"');
|
|
|
|
|
+ }
|
|
|
|
|
+ }
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('firmware rejects keys only some clients use', () {
|
|
|
|
|
+ String replyTo(String send) =>
|
|
|
|
|
+ (rejections.firstWhere((r) => r['send'] == send)['reply'] as List)
|
|
|
|
|
+ .single
|
|
|
|
|
+ as String;
|
|
|
|
|
+ expect(replyTo('cmd get grndr_cnt\n'), 'cmd get NOT OK');
|
|
|
|
|
+ expect(replyTo('cmd set tmpoff 5\n'), 'cmd set NOT OK');
|
|
|
|
|
+ expect(replyTo('cmd get pd1imm\n'), 'cmd get NOT OK');
|
|
|
|
|
+ expect(replyTo('cmd get tmpsp\r\n'), 'cmd get NOT OK');
|
|
|
|
|
+ });
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ group('V10 firmware conformance: machine events', () {
|
|
|
|
|
+ test('a 6 s shot is timed from the firmware sht frames', () {
|
|
|
|
|
+ final lines = scenarioLines('shot_6s');
|
|
|
|
|
+ var state = MachineState();
|
|
|
|
|
+ var sawBrewing = false;
|
|
|
|
|
+ for (final line in lines) {
|
|
|
|
|
+ state = MeCoffeeProtocol.parse(line, state);
|
|
|
|
|
+ sawBrewing |= state.isBrewing;
|
|
|
|
|
+ }
|
|
|
|
|
+ expect(sawBrewing, isTrue);
|
|
|
|
|
+ expect(state.isBrewing, isFalse);
|
|
|
|
|
+ expect(state.shotTimer, 6);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('a shtmx cutoff keeps the cutoff duration, not the release', () {
|
|
|
|
|
+ final state = parseAll(scenarioLines('shot_cutoff_shtmx_2'));
|
|
|
|
|
+ expect(state.isBrewing, isFalse);
|
|
|
|
|
+ expect(state.shotTimer, 2);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('preinfusion gap is included in the shot duration', () {
|
|
|
|
|
+ final state = parseAll(scenarioLines('shot_preinfusion_1s_gap_1s'));
|
|
|
|
|
+ expect(state.shotTimer, 5);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('steam marker, steam setpoint and return to brew', () {
|
|
|
|
|
+ final lines = scenarioLines('steam_3s');
|
|
|
|
|
+ var state = MachineState();
|
|
|
|
|
+ var sawSteam = false;
|
|
|
|
|
+ for (final line in lines) {
|
|
|
|
|
+ state = MeCoffeeProtocol.parse(line, state);
|
|
|
|
|
+ if (state.isSteaming) {
|
|
|
|
|
+ sawSteam = true;
|
|
|
|
|
+ if (line.startsWith('tmp ')) expect(state.targetTemperature, 125.0);
|
|
|
|
|
+ }
|
|
|
|
|
+ }
|
|
|
|
|
+ expect(sawSteam, isTrue);
|
|
|
|
|
+ expect(state.isSteaming, isFalse);
|
|
|
|
|
+ expect(state.targetTemperature, 101.0);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ for (final name in ['steam_reaching_tmpstm', 'steam_start_above_tmpstm']) {
|
|
|
|
|
+ test('$name: steam persists while the heater cycles', () {
|
|
|
|
|
+ final lines = scenarioLines(name);
|
|
|
|
|
+ final start = lines.indexOf('pid 65535 0 0 0 OK');
|
|
|
|
|
+ final end = lines.lastIndexWhere(
|
|
|
|
|
+ (l) => l.startsWith('tmp ') && l.split(' ')[2] == '12500',
|
|
|
|
|
+ );
|
|
|
|
|
+ expect(start, greaterThanOrEqualTo(0));
|
|
|
|
|
+ var state = MachineState();
|
|
|
|
|
+ for (var i = 0; i < lines.length; i++) {
|
|
|
|
|
+ state = MeCoffeeProtocol.parse(lines[i], state);
|
|
|
|
|
+ if (i >= start && i <= end) {
|
|
|
|
|
+ expect(state.isSteaming, isTrue, reason: lines[i]);
|
|
|
|
|
+ }
|
|
|
|
|
+ if (lines[i].startsWith('pid ') && state.isSteaming) {
|
|
|
|
|
+ final heaterOn = lines[i] != 'pid 0 0 0 0 OK';
|
|
|
|
|
+ expect(state.isHeating, heaterOn, reason: lines[i]);
|
|
|
|
|
+ expect(state.heatingPower, heaterOn ? 1.0 : 0.0, reason: lines[i]);
|
|
|
|
|
+ }
|
|
|
|
|
+ }
|
|
|
|
|
+ expect(state.isSteaming, isFalse);
|
|
|
|
|
+ expect(state.targetTemperature, 101.0);
|
|
|
|
|
+ });
|
|
|
|
|
+ }
|
|
|
|
|
+
|
|
|
|
|
+ test('power switch off reports zero heating', () {
|
|
|
|
|
+ final state = parseAll(scenarioLines('power_switch_off'));
|
|
|
|
|
+ expect(state.heatingPower, 0);
|
|
|
|
|
+ expect(state.isHeating, isFalse);
|
|
|
|
|
+ });
|
|
|
|
|
+
|
|
|
|
|
+ test('sensor range switch above 110 C is transparent to the client', () {
|
|
|
|
|
+ final lines = scenarioLines('sensor_saturated_range_switch');
|
|
|
|
|
+ final temps = <double>[];
|
|
|
|
|
+ var state = MachineState();
|
|
|
|
|
+ for (final line in lines) {
|
|
|
|
|
+ state = MeCoffeeProtocol.parse(line, state);
|
|
|
|
|
+ if (line.startsWith('tmp ')) temps.add(state.temperature);
|
|
|
|
|
+ }
|
|
|
|
|
+ expect(temps.reduce((a, b) => a > b ? a : b), closeTo(129.79, 1e-9));
|
|
|
|
|
+ expect(temps.last, closeTo(79.94, 1e-9));
|
|
|
|
|
+ });
|
|
|
|
|
+ });
|
|
|
|
|
+}
|